11

Rinnai Error Code 11 - Ignition Failure (No Flame Detected)

Medium Severity

The tankless water heater attempts ignition, but the flame rod sensor does not detect a stable burner flame within the required ignition window.

Appliance: Rinnai Water Heaters & Boilers
Estimated Time: 20 minutes
Tools Required: Phillips screwdriver, fine steel wool
Advertisement - Error Code Top Slot
⚠ Common Symptoms & Observations

No hot water from faucets; heater clicks several times trying to fire up; controller beeps and flashes Code 11.

🔍 Root Causes for Code 11
🔧 Step-by-Step DIY Troubleshooting & Fix Guide
1
Verify the gas isolation valve right below the water heater is aligned parallel with the pipe (fully open).
2
Check other gas appliances (like kitchen stove) to confirm home gas supply is active.
3
Inspect the PVC/polypropylene exhaust vent on the exterior wall to ensure leaves, bird nests, or snow are not blocking air exhaust.
4
Clean the flame sensor: Remove the front cover panel (4 screws), locate the flame rod with ceramic insulation, and gently rub the metal rod with fine steel wool to remove carbon soot.
🔄 Master Reset Procedure for Rinnai

Press the Power button on the remote temperature controller OFF and ON twice to clear Code 11.

Technician Tip: If the error code reappears immediately after a hard reset, the control board has detected an active electrical open circuit or failed component that requires physical inspection.